Contact
  • Hydraulic Brands
  • Product Catalogue
  • Hydraulic Power Packs & System Design
  • Technical Knowledge Hub
  • Ebooks & Resources
  • Industries, Sectors, Markets
  • About Us
    • About Us
    • Testimonials
    • Case Studies
    • Awards, Recognition & Global Trust
    • Official UK Government Export Champions
    • ISO 9001 Quality Management
    • Hydraulics Online Highlights & News
    • Community Action
    • Honoured by His Majesty The King
  • Contact Us

Contact Information

Email: sales@hydraulicsonline.com

UK: 01270 872528

International: +44 (0)1270 872528

Units 2 & 3 Townend Farm
Audley Road
Alsager
Cheshire ST7 2QR
United Kingdom
Language:
Quick Quote

Quick Quote

*required

Drop files here or
Max. file size: 5 MB, Max. files: 3.
    Newsletter SignUp
    Terms & Conditions*

    You can now access our world-trusted expertise and product range, wherever you are, at the click of a button
    Download our app now, keep us at your fingertips and save time in future!

    HomeProductsAll Hydraulic BrandsEaton VickersEaton Vickers Hydraulic ValvesEaton Vickers Relief Valves
    Eaton-Vickers-relief-valves
    Eaton-Vickers-relief-valves
    Eaton Eaton Hydraulic Valves Eaton Vickers Eaton Vickers Hydraulic Valves Hydraulic Valves Pressure Relief Valves

    Eaton Vickers Relief Valves

    The Eaton Vickers relief valve range includes inline direct-acting and inline pilot-operated valves. They provide pressure protection to the hydraulic system to maintain long-term dependability.

    The range comprises:

    Model 32107 circuit relief valve | A top assembly body and relief valve.  It uses different (direct-acting) cartridges or a plug, with options for fixed or adjustable cartridges. When set lower than the system relief, this circuit relief valve limits the working pressure to a particular circuit. In this application, the valve must have the flow capacity to handle the total pump flow:

    • Maximum flow through relief valve is 57 litres/minute;
    • Relief valve setting range: 47 to 276 bar (675 to 4,000 psi);
    • Standard relief valve setting: 138 bar (2,000 psi);
    • Housing rated pressure: 345 bar (5,000 psi).

    Model 32107 system relief valve | A top assembly body and relief valve. It uses fixed pilot-operated cartridges or a plug. As a system relief valve, it regulates maximum working pressure in hydraulic systems and protects the hydraulic system or machine structure:

    • Maximum flow through relief valve is 75.7 litres/minute;
    • Relief valve setting range from 103 to 241 bar (1,500 to 3,500 psi);
    • Housing rated pressure to 345 bar (5,000 psi).

    Model 32112 system relief valve | A top assembly body and relief valve. It uses different relief cartridges or a plug, with options for fixed pilot-operated or fixed direct-acting cartridges. As a system relief valve, it regulates maximum working pressure in hydraulic systems and protects the hydraulic system or machine structure:

    • Maximum flow through relief valve is 132.5 litres/minute;
    • Relief valve setting range from 69 to 241 bar (1,000 to 3,500 psi);
    • Housing rated pressure to 345 bar (5,000 psi).

    Model 32060 inline crossover relief valve | Fixed pilot-operated inline crossover relief valve. It is used in a closed-loop or open-loop motor circuit. The purpose of the high-pressure relief valve in the propulsion pump is to relieve the pump of excessive high pressure when the vehicle encounters a heavy load or stalls:

    • Rated flow to 76 litres/minute;
    • Maximum combined pump and load generated flow of 152 litres/minute;
    • Relief valve setting range from 34.5 to 207 bar (500 to 3,000 psi).

    RM3 and FM3 overload relief valve | The RMS Eaton Vickers relief valve is an internally pilot-operated valve that provides pressure protection to the hydraulic system. FM3 is a bypass type pressure compensated flow control and a relief valve. It is used in applications where a constant actuator speed is required in the face of varying pump output:

    • Controlled flow rate up to 94.6 litres/minute;
    • Relief valve setting range from 35 to 175 bar (500 to 2,500 psi);
    • Maximum operating pressure to 175 bar (2,500 psi).

    Contact us for further technical details and configuration options on Eaton Vickers relief valves.

    Quick Quote Go Back

    Contact Us for further technical details and configuration options.

    Subscribe to our newsletter
    Twitter Facebook LinkedIn YouTube
    • Hydraulics Online
    • About Us
    • Contact Us
    • ISO 9001 Quality Management
    • Community Action
    • Press Enquiries
    • FAQs
    • Discover
    • Product Catalogue
    • All Hydraulic Brands
    • Our Markets
    • Testimonials
    • Case Studies
    • News & Highlights
    • UNSDGs
    • Our Policies
    • Terms and Conditions
    • Privacy Policy
    • Anti-Bribery & Corruption
    • Modern Slavery Transparency Statement
    • Business Partner Code of Conduct
    • Cookie Policy
    • Knowledge & Expertise
    • Hydraulic Power Packs and System Design
    • Fluid Power Technical Knowledge Hub
    • Hydraulic Repairs

    © 2026 Hydraulics Online. All rights reserved.

    Accepted payment methods