Eaton Vickers Relief Valves
The Eaton Vickers relief valve range includes inline direct-acting and inline pilot-operated valves. They provide pressure protection to the hydraulic system to maintain long-term dependability.
The range comprises:
Model 32107 circuit relief valve | A top assembly body and relief valve. It uses different (direct-acting) cartridges or a plug, with options for fixed or adjustable cartridges. When set lower than the system relief, this circuit relief valve limits the working pressure to a particular circuit. In this application, the valve must have the flow capacity to handle the total pump flow:
- Maximum flow through relief valve is 57 litres/minute;
- Relief valve setting range: 47 to 276 bar (675 to 4,000 psi);
- Standard relief valve setting: 138 bar (2,000 psi);
- Housing rated pressure: 345 bar (5,000 psi).
Model 32107 system relief valve | A top assembly body and relief valve. It uses fixed pilot-operated cartridges or a plug. As a system relief valve, it regulates maximum working pressure in hydraulic systems and protects the hydraulic system or machine structure:
- Maximum flow through relief valve is 75.7 litres/minute;
- Relief valve setting range from 103 to 241 bar (1,500 to 3,500 psi);
- Housing rated pressure to 345 bar (5,000 psi).
Model 32112 system relief valve | A top assembly body and relief valve. It uses different relief cartridges or a plug, with options for fixed pilot-operated or fixed direct-acting cartridges. As a system relief valve, it regulates maximum working pressure in hydraulic systems and protects the hydraulic system or machine structure:
- Maximum flow through relief valve is 132.5 litres/minute;
- Relief valve setting range from 69 to 241 bar (1,000 to 3,500 psi);
- Housing rated pressure to 345 bar (5,000 psi).
Model 32060 inline crossover relief valve | Fixed pilot-operated inline crossover relief valve. It is used in a closed-loop or open-loop motor circuit. The purpose of the high-pressure relief valve in the propulsion pump is to relieve the pump of excessive high pressure when the vehicle encounters a heavy load or stalls:
- Rated flow to 76 litres/minute;
- Maximum combined pump and load generated flow of 152 litres/minute;
- Relief valve setting range from 34.5 to 207 bar (500 to 3,000 psi).
RM3 and FM3 overload relief valve | The RMS Eaton Vickers relief valve is an internally pilot-operated valve that provides pressure protection to the hydraulic system. FM3 is a bypass type pressure compensated flow control and a relief valve. It is used in applications where a constant actuator speed is required in the face of varying pump output:
- Controlled flow rate up to 94.6 litres/minute;
- Relief valve setting range from 35 to 175 bar (500 to 2,500 psi);
- Maximum operating pressure to 175 bar (2,500 psi).
Contact us for further technical details and configuration options on Eaton Vickers relief valves.
Contact Us for further technical details and configuration options.